KNOWLEDGE BASE

Technical Articles

Ring Formation — What to Check First

Use shell-temperature pattern, pressure, discharge behavior and operating history before changing major parameters.

Low FeM — A Practical Diagnostic Order

Confirm analysis, then review feed quality, temperature profile, coal availability, retention conditions and oxidation.

High Coal Consumption

Evaluate Coal/DRI together with yield, FC, moisture, C/Fe and carbon input rather than looking at coal feed alone.

ESP Tripping

Classify electrical, process, dust-handling and mechanical causes before corrective action.